Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
The scattering method turbidity sensor is a common type of turbidity analyzer sensor. The working principle of the scattering method turbidity sensor is relatively simple. It evaluates the turbidity of the liquid by measuring the scattering of light in the liquid. Scattering occurs when light passes through suspended solids or particles, so the intensity of the scattered light can be used to infer the level of turbidity. Scattering turbidity sensors are usually characterized by fast response and can provide accurate turbidity measurements in a short time. This is important for applications that require real-time monitoring and control of turbidity. Online turbidity sensor can be applied to a wide range of turbidity, from weak scattering to highly turbid liquids can be measured
The industrial online pH ORP controller APX1-C1Z developed and produced by Delfino is a cheap instrument that meets the rich output needs of customers. It has a 0/4-20mA current output and a two-wire RS485 communication interface, supports the Modbus communication protocol, and can meet the needs of customers with different output data. 2 multifunctional relays can control pH dosing, sensor cleaning and temperature control. The protection level of the online pH meter is IP66, which is...
A pH sensor is a sensor used to measure the pH of a solution, and its principle is based on electrochemical reactions. An analog pH sensor usually consists of a glass electrode and a reference electrode. The inside of the glass electrode is coated with a glass membrane that reacts with hydrogen ions in the solution to generate a potential difference to measure the pH of the solution. This ASP300 online pH sensor is a combination electrode with double salt bridge design, long service life and...
A combination pH electrode is an analog pH sensor that combines a glass pH electrode and a reference electrode. It consists of a pH-sensitive glass membrane and a reference electrode, allowing simultaneous measurement of pH and temperature of the sample. The combination pH electrode has many advantages, it can directly measure samples containing suspended solids or sediments without filtering or stirring. It can be used in high-concentration salt solution without interference. The principle of...
The inline pH sensor is an important instrument used to measure the pH of a solution, and its service life is affected by many factors, including frequency of use, environmental conditions, sample properties, etc. Generally speaking, the service life of the pH electrode is between 6 months and 2 years, but the specific situation needs to be determined according to the actual usage. Choosing a good durable pH sensor requires consideration of many factors, including measurement range, response...
An industrial pH sensor is an electrochemical sensor used to measure the pH of a solution, which plays a very important role in industrial processes. The PH value is an index to measure the acidity and alkalinity of a solution. For many industrial processes, controlling the PH value is very critical. The following are the importance of industrial pH electrodes in industrial processes: Control the reaction process: In many industrial processes, the change of pH value will affect the reaction...
Ammonia nitrogen refers to the total nitrogen content of ammonia and amino compounds in water. In the process of sewage treatment, ammonia nitrogen is a very important indicator, because it can reflect the degree of decomposition of organic matter and the content of nitrogen in sewage. Therefore, sewage plants need to monitor the value of ammonia nitrogen to ensure the quality and effect of sewage treatment. In the sewage treatment process, the monitoring of ammonia nitrogen is mainly...
Ozone O3 is a molecule composed of three oxygen atoms and is a strong oxidizing agent. It is produced in nature by means such as ultraviolet radiation and electric shock discharge, and is commonly found in the ozone layer in the atmosphere. The advantage of ozone as a disinfectant is that it can quickly kill bacteria, viruses and other microorganisms, and is more efficient than traditional disinfectants. During the disinfection process, no harmful residue is left, and it will not cause...
Chlorine dioxide can be used to disinfect and purify water sources. It is usually used in the water treatment industry, and in the tap water industry, monitoring chlorine dioxide is very important. Usually, before the raw water from the waterworks enters the treatment system, it is necessary to monitor the chlorine dioxide in the raw water to know whether there is chlorine dioxide pollution in the raw water. In the process of water treatment, the concentration of chlorine dioxide also needs to...
Chlorine dioxide (ClO2) is a colorless gas with a pungent odor. It is produced by the reaction of chlorine and oxygen under certain conditions. Chlorine dioxide has strong oxidizing and bactericidal properties, so it is widely used in many occasions. Monitoring water quality for chlorine dioxide levels can assess whether the concentration of disinfectant is high enough to achieve effective disinfection. Delfino's chlorine dioxide sensor is designed for continuous monitoring of water quality...
Chlorine is one of the common water treatment agents used to disinfect tap water from bacteria and pathogens. Monitoring the total chlorine value at the waterworks can ensure that the concentration of chlorine disinfectants in the tap water is within a safe range, which can effectively kill bacteria and pathogens without adversely affecting human health. In addition, monitoring the total chlorine value can also detect leakage or excessive dosage of chlorine disinfectant in tap water in time to...
Peracetic acid is a strong oxidant that can quickly kill microorganisms such as bacteria, viruses and fungi in water, and plays an important role in water quality safety. Peracetic acid will be decomposed into water and oxygen after being used in water, without leaving any harmful substances, and has no pollution to the environment. It can effectively inhibit the reproduction of microorganisms in water, extend the shelf life of water, and prevent water from deteriorating. Peracetic acid can be...
Total chlorine refers to the sum of free chlorine and combined chlorine in water, which is an indicator used to measure the content of chlorine in water. Residual chlorine refers to the content of chlorine that is not consumed after adding disinfectant to water. It is the residue of a disinfectant used to keep water sanitizing. The sensors used to measure the residual chlorine value and total chlorine value of water are different. Daruifuno's total chlorine sensor CP4.0 is specially designed...
Chlorine is a common disinfectant used to kill bacteria, viruses and other microorganisms in water. Monitoring the total chlorine level can ensure that the chlorine concentration in the water is within the safe range to effectively disinfect the water source. Chlorine can react with organic matter to produce carcinogens such as chloroform. Monitoring total chlorine levels can help identify excessive chlorine concentrations in water and avoid potential health risks. Chlorine can also react with...
The DUC2-TU turbidity controller can be connected with the turbidity sensor developed by Daruifuno using the principle of infrared scattering to measure the concentration of suspended substances in water, and then convert the measurement results into electrical signals for processing and monitoring. The role of the sewage plant turbidity transmitter is to monitor and control the turbidity in the sewage treatment process to ensure that the turbidity of the effluent meets the specified standards....
The drinking water industry has strict requirements on turbidity values. Turbidity refers to the ability of suspended particulate matter in water to scatter light, and is an index to measure the clarity of water quality. According to the standards of the World Health Organization (WHO), the turbidity of drinking water should be as low as possible, and generally should not exceed 1 NTU (turbidity unit). In some countries and regions, such as the United States and the European Union, the...
This digital infrared turbidity analyzer adopts the 90° near-infrared light scattering principle and conforms to the ISO7027 standard to measure the turbidity of water samples. DUC2-TU turbidity controller can be connected with the digital turbidity sensor to measure the water turbidity values. The controller has two relays and two 4-20mA current output. As a digital turbidity controller, it has RS485 interface and support Modbus protocol. Features Of Turbidity Controller ● Compatible with all...
Turbidity refers to the content of suspended matter in water, usually expressed by the number or concentration of particulate matter in water. These particles can be organic matter, inorganic matter, microorganisms, etc. suspended in water, or sediment, silt, etc. in water. Turbidity is an important indicator of water quality, which can reflect the content of impurities in water and the transparency of water, and is one of the important parameters in water quality monitoring. Monitoring the...
OWA030, OWA350, OWA361 oil in water sensor, using the principle of ultraviolet fluorescence analysis, compared with several commonly used methods, the fluorescence method is more efficient, quicker and has better repeatability, and can be monitored in real time online. The sensor has better repeatability and stability to detect soluble and emulsified oils. In addition, OWA361 is equipped with an automatic cleaning brush, which can eliminate air bubbles and reduce the impact of contamination on...
Pool turbidity monitoring is very important as it ensures the quality and cleanliness of the pool water. Turbidity in pool water refers to the concentration of suspended and dissolved matter in the water, which includes dirt, sweat, grease, chemicals, and more. If the turbidity of swimming pool water is too high, it will not only affect the sight of swimmers, but also may lead to health problems such as infectious diseases and allergies. The turbidity value of swimming pool water usually needs...
Chloride ions are common water treatment agents used for disinfection and sterilization. During water treatment, chloride ions can kill bacteria, viruses and other microorganisms, thus ensuring the safety of drinking water. However, high concentrations of chloride ions may have a negative impact on human health. High concentrations of chloride ions may interact with organic matter to produce carcinogens and have adverse effects on human liver and kidneys. High concentrations of chloride ions...
Ultrasonic Immersion Sewage Level Sensor Wiring Diagram of Ultrasonic water Level Sensor level meter
Specifications Resistance battery sewage level sensor 1.Accuracy:0.25~0.5%FS 2.RS485 Optional 3.To metery you are the word ackaging & Shipping
Ultrasonic Sewage level sensor Wiring Diagram of Diesel fuel tank level gauge
Sewage level sensor MT100LR Structure Diagram Installation Diagram Tech
Product Description Battery hydraulic sewage level sensor
Ultrasonic Immersion Sewage Level Sensor Wiring Diagram of Ultrasonic water Level Sensor level meter
Specifications Resistance battery sewage level sensor 1.Accuracy:0.25~0.5%FS 2.RS485 Optional 3.To metery you are the word ackaging & Shipping
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.