The online dissolved oxygen sensor of the optical method uses the fluorescence method to measure the dissolved oxygen content in water. The dissolved oxygen probe uses advanced optical technology to achieve high-precision dissolved oxygen measurement. The response speed is fast, and it can monitor the change of oxygen in water in real time. The optical dissolved oxygen sensor has high stability and can work stably for a long time. The protection level is IP68, and it can work continuously underwater. The maintenance and calibration of the dissolved oxygen sensor is relatively simple. The optical method does not require electrolyte and routine maintenance. The service life of the fluorescent cap is about 1 year, and the reliability is high
ORP is the abbreviation of Oxidation-Reduction Potential, also known as Redox Potential. It is a physical quantity that measures the intensity and direction of redox reactions in solution. The principle of the ORP probe is to use electrode to measure the potential of the oxidation-reduction reaction in the solution. The redox probes are usually made of materials such as silver/silver chloride or platinum/platinum black. When the electrode comes into contact with a redox agent in solution, an...
How to choose a durable, high-precision inline pH probe? Buyers are concerned about the following aspects when purchasing a pH electrode: first, the accuracy and stability of the electrode, which needs to ensure the accuracy and repeatability of the measurement results; second, the scope of application of the electrode, which needs to be based on actual needs Select the appropriate electrode type and measurement range; the third is the price and cost performance of the electrode, you need to...
Daruifuno's online ammonia nitrogen controller is a digital instrument. It can be connected with the digital ammonia nitrogen sensor of the ion selection method to realize real-time monitoring of the ammonia nitrogen value of the water quality. The ammonia controller is widely used in water treatment plants, sewage plants, industrial production processes, etc., where ammonia nitrogen content needs to be monitored. The ammonia controller has two SPST relays for control system and clean control....
Sewage plants need to control the value of ammonia nitrogen, mainly to protect the environment and human health. The discharge of sewage with high ammonia nitrogen content into the natural environment will lead to problems such as eutrophication of water body and excessive algae reproduction, which will seriously affect the survival of aquatic organisms and the stability of water quality. At the same time, sewage with high ammonia nitrogen content will also pose a threat to human health. For...
Chlorine dioxide can be used to disinfect and purify water sources. It is usually used in the water treatment industry, and in the tap water industry, monitoring chlorine dioxide is very important. Usually, before the raw water from the waterworks enters the treatment system, it is necessary to monitor the chlorine dioxide in the raw water to know whether there is chlorine dioxide pollution in the raw water. In the process of water treatment, the concentration of chlorine dioxide also needs to...
Chlorine is a common disinfectant used to kill bacteria, viruses and other microorganisms in water. Monitoring the total chlorine level can ensure that the chlorine concentration in the water is within the safe range to effectively disinfect the water source. Chlorine can react with organic matter to produce carcinogens such as chloroform. Monitoring total chlorine levels can help identify excessive chlorine concentrations in water and avoid potential health risks. Chlorine can also react with...
Hydrogen peroxide is a chemical substance with the chemical formula H2O2, a colorless, tasteless, odorless liquid with strong oxidizing properties. Hydrogen peroxide is widely used in water disinfectants because it can effectively kill germs, viruses and other microorganisms in water, thus making water safer and more hygienic. The disinfecting action of hydrogen peroxide is achieved through its oxidizing properties. Hydrogen peroxide can react with organic substances and microorganisms in water...
The DUC2-TU turbidity controller can be connected with the turbidity sensor developed by Daruifuno using the principle of infrared scattering to measure the concentration of suspended substances in water, and then convert the measurement results into electrical signals for processing and monitoring. The role of the sewage plant turbidity transmitter is to monitor and control the turbidity in the sewage treatment process to ensure that the turbidity of the effluent meets the specified standards....
Turbidity refers to the content of suspended matter in water, usually expressed by the number or concentration of particulate matter in water. These particles can be organic matter, inorganic matter, microorganisms, etc. suspended in water, or sediment, silt, etc. in water. Turbidity is an important indicator of water quality, which can reflect the content of impurities in water and the transparency of water, and is one of the important parameters in water quality monitoring. Monitoring the...
OWA030, OWA350, OWA361 oil in water sensor, using the principle of ultraviolet fluorescence analysis, compared with several commonly used methods, the fluorescence method is more efficient, quicker and has better repeatability, and can be monitored in real time online. The sensor has better repeatability and stability to detect soluble and emulsified oils. In addition, OWA361 is equipped with an automatic cleaning brush, which can eliminate air bubbles and reduce the impact of contamination on...
Chloride ions are common water treatment agents used for disinfection and sterilization. During water treatment, chloride ions can kill bacteria, viruses and other microorganisms, thus ensuring the safety of drinking water. However, high concentrations of chloride ions may have a negative impact on human health. High concentrations of chloride ions may interact with organic matter to produce carcinogens and have adverse effects on human liver and kidneys. High concentrations of chloride ions...
The online digital pH sensor developed and produced by Daruifuno is a sensor for online pH monitoring of water quality. Digital electrodes have higher measurement accuracy, can provide accurate pH measurement results, and output them in real time. The difference between digital sensors and analog pH sensor is mainly here that digital sensors can directly provide real-time digital output without using additional conversion devices. This is due to its internal RS485 interface, which supports...
The digital pH sensor is an instrument used to measure the pH of water or other liquids. Its principle is based on the change of the acid-base indicator to measure the pH of the liquid. The pH sensor changes the color of the indicator by contacting the liquid with an acid-base indicator, and then measures the concentration of hydrogen ions (H+) in the liquid through an electrode to determine the pH of the liquid. The working principle of the pH sensor is relatively simple, but it is very...
ORP is an abbreviation for Oxidation-Reduction Potential, also known as Oxidation-Reduction Potential Value. It is an index to measure the redox ability of a solution. The digital ORP sensor developed and produced by Daruifuno has an RS485 digital interface, which can be directly connected to industrial control equipment to output data. It is necessary to monitor the value of ORP in the waterworks, especially in some aspects of water treatment. For example, monitoring the ORP value in raw water...
DPH790 online digital pH probe adopts glass electrode method, and the measuring range is 0~14pH. The advantage of the digital pH sensor is that it can achieve reliable and interference-free signals. It can internally convert its own measurement signals from analog signals to digital signals to ensure that reliable digital signals can also be obtained in long-distance situations. This digital ph probe RS485 can be plug-and-play, internally stores calibration data, can be calibrated offline, and...
It is very necessary to monitor the conductivity value of wastewater, which can judge the content of dissolved solids in wastewater and the pollution degree of water quality. Conductivity refers to the magnitude of the voltage drop across the conductor when the current passes through a conductor of unit length and unit cross-sectional area, which is related to the ion concentration and ion species in the solution. The higher the dissolved solids content in the wastewater, the higher the...
The DUC2-DO dissolved oxygen controller independently developed and produced by Daruifuno can be connected with an optical dissolved oxygen sensor to realize continuous monitoring of the dissolved oxygen value of water quality. In addition to having 2 relays, RS485 interface, time and historical data functions, the dissolved oxygen controller has two 4-20mA current outputs. This enables the ability to control oxygenation using a dissolved oxygen controller. First use a dissolved oxygen sensor...
The infrared scattering method uses the scattering characteristics of solid particles in the sludge to infrared light to measure the concentration. When infrared light passes through a sludge sample, the solid particles scatter the light, and the intensity of the scattered light is proportional to the concentration of the particles. MLSS series sludge concentration sensors provide different measurement ranges, and users can choose according to their needs. Shell material also has the choice of...
Chlorine dioxide is used for disinfection in industrial production processes, including drinking water treatment, food processing, pharmaceuticals, pulp and paper production, etc. Chlorine dioxide is a commonly used disinfectant in the food processing industry. It can effectively kill bacteria, viruses and other microorganisms in food to ensure food safety and hygiene. The link that needs to use chlorine dioxide for disinfection is usually the water treatment link in the production process....
The ORP probe is an electrode used to measure the redox potential in a solution. It can determine the redox capacity of a solution by measuring the potential difference between the electrode and the reference electrode. The difference between a digital ORP probe and an analog ORP sensor is that the digital ORP electrode can directly output a digital signal, while the analog ORP electrode converts the signal to a digital signal through an analog signal converter. ORP probes are mainly used in...
Liquid molten steel plant using disposable s type 10 to 1500 ppm dissolved oxygen saturation probe P
Product Description
Products Description
Products Description
Products Description
Liquid molten steel plant using disposable s type 10 to 1500 ppm dissolved oxygen saturation probe P
Product Description
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.